Maximum section length with occupancy detector
Maximum section length
Section longer than 7 meters
Due to electrical interference, excessively long sections should not be used. Reporting sections longer than 7m are not possible (at least with Littfinski).
Monitored track sections
Quote from a message:
Isolated track sections that are to be monitored from the perspective of track occupancy detectors, have inductive and capacitive components that, depending on the length of the section, cause increasing electrical background noise. From a monitored length of several meters, this leads to a continuous occupancy indication, even if no electrical load is present on this section. This applies to all track occupancy detectors, regardless of the manufacturer. The mentioned 7m is a perfectly realistic length. . Best regards . Peter Littfinski
Are all manufacturers affected?
No, that does not apply to all manufacturers.
The reason for this 'self-occupancy' lies in the nature of the control signals used. Both DCC and Märklin/Motorola use a positive-width encoded voltage; whenever the polarity of the signal changes, a small charging current flows briefly into the line capacitance – this current is greater the longer the connected line.
Bei einfach aufgebauten Belegtmeldern wird einfach die mittlere Stromaufnahme gemessen, darum entsteht ab einer bestimmten Länge eine Belegungsmeldung, ohne dass ein echter Verbraucher vorhanden ist.
Wenn hingegen der Belegtmelder das Gleissignal auswertet, sich darauf einsynchronisiert und während des Umpolens ganz kurz 'wegsieht' (nur ein paar µs), dann wird nur ein tatsächlicher Verbrauch gemessen und Leitungs- oder Gleislängeneinflüsse sind weg.
Diese Info wurde in einem Beitrag im Forum veröffentlicht.