Intellibox 2neo
No connection
Unfortunately, the Intellibox II neo and TrainController cannot be connected when "Intellibox2neo" is selected. It only works when "Intellibox2" is selected.
Incorrect Baud Rate
Model railroader "modellbahnhof" describes in the forum:
An IB2neo connects to the central unit when the baud rate in the IB2neo is set to 115000 baud.
However, if the baud rate in the IB2neo is set to 19200 baud, then the IB2neo can be registered as IB2 and not as IB2neo.
Die Baudrate in der IB2neo muss also von 19200 Baud auf 115000 Baud umgestellt werden.
Weblinks
- Quelle: Forum
- -- Uslex 11:53, 9. Nov. 2025 (UTC)